FV32LED

 

 

Tightness level

 

 

Optical compartment

 

IP 66 (*)

Impact resistance (glass)

IK 08 (**)

Nominal voltage

 

120V-277V
50/60Hz

Electrical class 

 

1-US and I EU

Vibration level

1.5G (***) (14.67m/s²)

Certifications

ANSI/UL 1598 / CAN/CSA C22.2 No. 250.0-08, 3rd Ed.
UL 8750, 1st Ed. REV10/17/2012, CAN/CSA-22.2 No. 250.13-12

(*) according to IEC - EN 60598 (**) according to IEC - EN 62262
(***) according to ANSI C136.31-2010

Materials

 

 

Body

 

Extruded aluminium profile

Side plates

Die-cast aluminium

Finishing

 

Aluminium

 

 

A COMPLETE SOLUTION FOR LIGHTING TUNNEL ENTRANCES, THRESHOLD AND INTERIOR ZONES

       

LENSOFLEX®2

FV32 LED luminaires are equipped with second generation LensoFlex®2 photometric engines that can be adapted to a wide range of different tunnel applications to
provide safety in all driving conditions.
This system is based upon the addition principle of photometric distribution. Each LED is associated with a specific lens that generates the complete photometric distribution of the luminaire. It is the number of LEDs in combination with the driving current that determines the intensity level of the light distribution.

MAXIMUM ENERGY SAVINGS

A minimal total cost of ownership was the driving force behind the development of the FV32 LED. It is equipped with LEDs and various dimming and remote management options for a dramatic reduction in energy consumption.

RELIABLE SOLUTION

The FV32 LED integrates 3 Schréder concepts to provide a reliable and effective solution for lighting the different zones of tunnels: 

 

  • ThermiX® - optimises heat extraction to maintain 90% of the nominal luminous flux at 100.000 hours of use up to a yearly average night temperature of 25°C
  • Power supplies - ensure 90% efficiency (standard supply current is 350mA to optimise the efficacy of the LEDs and maximise lifespan)
  • Control - bi-directional communication and failure detection can increase the reliability of the system.

 

OPTIONS

  • All types of mounting systems can be accomodated (please see Installation and Maintenance)
  • Cable gland installation
  • IP 69 for tunnels with high-pressure cleaning


Top and side view

 

 

 

 

 

 

FV32 LED

 

L

H

W1

W2

240 LEDs

49.82”

5.31”

11.31”

4.33”

160 LEDs

28.80”

5.31”

11.31”

4.33”

64 LEDs

24.00”

5.31”

11.31”

4.33”

FV32 LED (3rd Party Certified)

Lifetime residual flux @ tq 25°C (**)

 

Number of LEDs

Neutral White (4000K)

64 LEDs

120 LEDs

240 LEDs

@100,000 h

Current: 350mA

Nominal flux (lm)*

9600

18000

36000

90%

Power consumption (W)

64

126

252

(*) The real output flux is an indicative of LED flux @ tj 25°C based on LED manufacturer’s data.
The real flux output of the luminaire depends on environmental conditions (e.g. temperature and pollution) and the optical efficiency of luminaire.
Nominal flux depends on the type of LED in use and likely to change in accordance with the continuous and rapid developments in LED technology.
(**)In accordance with IES LM-80 - TM-21.

 

LIGHT DISTRIBUTIONS

LED optic 5098 - Narrow Passway

 FV32 LED

 

LED optic 5103 - Urban Tunnel

 FV32 LED

 

LED optic 5068 - Urban Tunnel

 FV32 LED

 

LED optic 5102 - Motorway Tunnel

 FV32 LED

 

LED optic 5096 - Motorway Tunnel

 FV32 LED

INSTALLATION

FLEXIBLE INSTALLATION

All types of mounting systems can be accomodated. Please contact us for your specific needs. 

 

 

 

 

I. Fixed suspended mountings

Direct

With 'Z'-shaped brackets

Swivelling

 

Swivelling and adjustable
(luminaire/wall distance)

 

II. Pull-out suspended mountings

Tilting

Horizontal (+-5°)

Swivelling and adjustable (3 directions)

A = 90mm with +/-10mm transversal adjustment

 

 

MAINTENANCE

UPGRADABLE TECHNOLOGY

FV32 LED luminaires are designed to meet our FutureProof concept and offer at the same time high flexibility for maintenance.
Both the photometric engine and the electrical supply can be replaced on-site to take advantage of any future technological developments.
Each LED module can be replaced individually.

 

Key features Maximum energy savings LensoFlex®2 for high-performance photometry, comfort and safety Flexible solution: extruded aluminium profile to adjust number of LEDs for tunnel requirements ThermiX®: maintains high performance over time Various inclination possibilites on-site for optimal photometry FutureProof: easy replacement of photometric engine and power supply on-site Control system can be integrated into the backbone system

Applications Tunnels

Ecosystems Tunnel

Contact us

+1 (847) 621-5130 Email us

Information

Request a brochure Print this page

Your browser is currently not supported

Don't worry, there is an easy fix. All you have to do is click the link below and follow the instructions.

outdatedbrowser.com