Design: Michel Tortel
Tightness level
Optical compartment
IP 66 (*)
Electronic compartment
Impact resistance
Glass
IK 08 (**)
Aerodynamic resistance (CxS)
Teceo 1
0.011m²
Teceo 2
0.014m²
Nominal voltage
230V - 50Hz
Electrical class
I or II (*)
(*) according to IEC - EN 60598 (**) according to IEC - EN 62262
Weight
9.6kg
17.5kg
Materials
Body + cover
Die-cast aluminium
Protector
Extra-clear flat glass
Colour
AKZO light grey 150 sanded
A minimal total cost of ownership was the driving force behind the development of the Teceo range. It is equipped with LEDs and various dimming and remote management options for a dramatic reduction in energy consumption. The Teceo luminaires offer a very competitive alternative to luminaires equipped with traditional light sources such as high-pressure sodium lamps.
Teceo luminaires have been equipped with second generation LensoFlex®2 photometric engines that have been specifically developed for lighting spaces where the well-being and safety of people using the environment are essential.
Using state-of-the-art technology, the Teceo luminaires have been designed to fufil the FutureProof concept. The photometric engine is IP 66 sealed to protect the LEDs and maintain performance over time. The optical unit can be easily removed, allowing real on-site replacement at the end of its service life in order to take advantage of future technological developments. This easy and rapid procedure reduces maintenance costs and contributes to reducing total cost of ownership. This FutureProof concept enables any version of the luminaire (Economy, Performance or Premium) to be easily upgraded at any stage during the service life.
All models can be equipped with a completely new "plug and go" LEDSafe® optical unit at any time.
With a conventional solution, the depreciation of the luminous flux over time leads to excess lighting and thus too much energy consumption when the luminaires are installed. The efficiency slowly declines to reach the minimum required level at the end of the installation's service life (graph A). The Teceo luminaires work differently by operating with a constant luminous flux (Constant Light Output - CLO).
They control precisely and autonomously their energy needs during the luminaires' life cycle to provide the required level constantly - no more and no less - throughtout the service life (graph B).
This can generate additional energy savings of up to 10% for a lifetime of 100,000 hours.
The right lighting is adapting precisely the quanity of light according to the real needs at a specific time (depending on daylight and more importantly activity in the area).
Dimming systems can generate substantial energy savings. The Teceo range can be equipped with different dimming and remote management systems.
Energy efficiency ratio
Lamp with small burner
Optical compartment tightness level
Limited upward flux (3%)
Limited mercury content of the light source
Lamp and gear set maintained efficacy
Electronics integration
Dimming
Remote management
Mercury free light source
Sustainable and recyclable materials
ISO 14001
Teceo 1 Teceo 2 H1 141mm 138mm H2 113mm 119mm L 607mm 788mm
H1
141mm
138mm
H2
W
318mm
439mm
OPTICS
LensoFlex®2
No. LEDs
Teceo 1: 16-24-...-48
Teceo 2: 56-64-...-144
Photometrical distributions
4
CCT LED
Neutral white (4250 K)
Warm white (3100K)
Cool white
FutureProof
LEDSafe® module
Pre-installed
Extra-clear
High efficiency
Embellishment plate
ELECTRICAL
Power range
Driving current
350mA
500mA
700mA
Constant Light Output(*)
Dimming/switching control
1-10V
Bi-Power
50%
Profile
Custom
Photo cell
OWLET remote mgt.
LuCo
Class II
Class I
Surge protection
10kV
Disconnector
Upon opening
MECHANICS
Mounting
∅ 42-60mm
2 M8 screws
stainless steel bar
∅ 76mm
Cover bracket holder
OTHERS
Gear plate
Pre-cabled
Custom length
Light grey
AKZO 150
All RAL and AKZO
included
O optional
not available
(*) only for versions equipped with 32 LEDs and more
LENSOFLEX®2
Teceo luminaires are equipped with second generation LensoFlex®2 photometric engines that have been specifically developed for lighting spaces where the well-being and safety of people using the environments are essential.This system is based upon the addition principle of photometric distribution. Each LED is associated with a specific lens that generates the complete photometric distribution of the luminaire. It is the number of LEDs that determines the intensity level of the light distribution.
PERFORMANCE AND FLEXIBILITY
The Teceo luminaires are equipped with photometric engines composed of modular quantities of LEDs so that they can offer a wide range of lumen packages. They can also be equipped with a variety of driving currents and dimming options.The Teceo luminaires can be adjusted on-site for optimal photometric performance.This flexibility ensures that the light distributions are specifically adapted to the real needs of the area to be lit.
Number of LEDs
Neutral white (4250K)
16 LEDs
24 LEDs
32 LEDs
40 LEDs
48 LEDs
@100.000h
Current: 350mA
nominal flux(lm*)
2200
3400
4500
5700
6800
90%
Power consumption (W)
19
28
37
45
54
Current: 500mA
Nominal flux (lm)*
3000
6000
7500
9000
27
41
53
65
78
Current: 700mA
3800
5800
7700
9700
11600
40
58
75
95
113
56 LEDs
64 LEDs
72 LEDs
80 LEDs
88 LEDs
96 LEDs
104 LEDs
112 LEDs
120 LEDs
128 LEDs
136 LEDs
144 LEDs
8000
9100
10200
11400
12500
13700
14800
16000
17100
18300
19400
20500
63
71
79
87
103
118
126
133
142
149
158
10500
12000
13500
15100
16600
18100
19600
21100
22600
24100
25600
27100
91
115
127
139
151
169
181
193
206
218
230
13600
15500
17500
21300
23300
25200
27200
29100
31100
-
130
148
173
190
208
226
243
260
277
296
(*) The nominal flux is an indicative LED flux @ tj 25°C based on LED manufacturer’s data. The real flux output of the luminaire depends on environmental conditions (e.g. temperature and pollution) and the optical efficiency of luminaire.Nominal flux depends on the type of LED in use and likely to change in accordance with the continuous and rapid developments in LED technology.To follow the progress of the luminous efficiency of the LEDs used, please visit our website.(**) In accordance with IES LM-80 - TM-21.
Narrow road configuration - LensoFlex®2 Optic 5098
For S classification according to CIE 115
Residential street configuration - LensoFlex®2 Optic 5103
For M4 classification according to CIE 115 - SR > 50% included
Urban road configuration - LensoFlex®2 Optic 5068
For M3 classification according to CIE 115 - SR > 50% included
Motorway configuration - LensoFlex®2 Optic 5102
For M3 classification according to CIE 115
Medium area configuration - LensoFlex®2 Optic 5120
Large area configuration - LensoFlex®2 Optic 5121
The Teceo luminaire can either be post-top or side-entry mounted.The Teceo luminares are fitted with an adjustable inclination system to facilitate photometric adjustments on-site for optimal photometric performance.
Using state-of-the-art technology, Teceo luminaires have been designed to fulfil the FutureProof concept. The photometric engine is IP 66 sealed to protect the LEDs and lenses from coming into contact with the outside environment and so maintain photometric performance over time. The optical unit be easily removed, allowing real on-site replacement at the end of its service life in order to take advantage of future technological developments. This easy and rapid procedure reduces maintenance costs and contributes to reducing the total cost of ownership. This FutureProof concept enables the luminaire to be easily upgraded to a LEDSafe® version or to take advantage of potential developments at any stage during the service life. All models (Economy, Performance and Premium) can be equipped with a completely new “plug and go” LEDSafe® optical unit at any time.
The Ito family of lighting brackets was designed specifically to offer an aesthetic coherence with the Teceo. This ensemble offers a complete solution for multiple urban and suburban applications.
A rear bracket version of the Teceo luminaire means that streets, side-streets and large pavements can be lit using the same luminaire design. The wall bracket allows the lighting of narrow streets as well as any areas where poles are not permitted; meeting all the needs of road and urban lighting.
If illegible, please open the PDF file of the brochure below
dddddddddddddddddv