ONYX
| Description | | Range of Sealsafe® IP 66 public lighting luminaires for lamps up to 600 W. The body consists of two parts made of painted die cast aluminium alloy, connected to each other on one side by two hinges and fitted with a stainless steel closing system. The optical compartment consists of a protector made of curved glass sealed onto a reflector made of deep drawn, polished and anodised aluminium.
Coating: polyester powder Standard colours: beige RAL 1013, red RAL 3004, blue RAL 5003, green RAL 6005, grey RAL 7035, black RAL 9005. | | ONYX 2 ST
The Onyx 2 ST model differs from the standard Onyx 2 model in two characteristics: • an integrated gasket ensures an IP 65 tightness level to the entire body. • a three-point closing system. | |
| Materials | |  | | GLASS PROTECTOR
The Onyx range is fitted with a tempered glass protector. The inherent qualities of the glass guarantee the uniformity over time of an optimal level of transparency: it does not yellow under the action of ultraviolet rays. | |
| Characteristics | | Optical compartment tightness level: IP 66 Sealsafe® (*) Control gear tightness level: - Onyx 2: IP 44 (*) - Onyx 3: IP 44 (*) - Onyx 2 ST: IP 65 (*) Aerodynamic resistance (CxS): - Onyx 2: 0,048 m2 - Onyx 3: 0,073 m2 Impact resistance (glass): IK 08 (**) Nominal voltage: 230 V – 50 Hz Electrical class: I or II (*) Weight (empty): - Onyx 2 / 2ST: 7,8 kg - Onyx 3: 11,4 kg
(*) according to standard IEC - EN 60598 (**) according to standard IEC - EN 62262 | |
| Exploded View | |  |
|
- Robustness and longevity: cover and body made of painted die cast aluminium alloy. Six standard colours. Other colours optional.
- Lampholder support plug.
- Stainless steel closing spring.
- Reflector made of deep drawn, polished and anodised aluminium.
- Prop made of galvanised steel.
- Tempered glass protector: curvature of the glass minimising light pollution, no yellowing caused by UV rays.
- Choice of lamps from 70 to 600 W.
- Maintenance and energy cost savings: the Sealsafe® system guarantees a high tightness level (IP 66). No internal cleaning is necessary: the reflector is sealed to the protector.
- Ease of maintenance: disconnectable and removable control gear plate.
- Installation flexibility: side entry or vertical installation.
- Connection terminal.
| |  |
| Installation flexibility: side entry or vertical installation. | |  |
| | ONYX 2ST
Three-point closure system, in die cast aluminium. Integrated neoprene gasket gives an IP 65 tightness level to the entire body. | |
| Dimensions | |  |
|
|
L |
H |
I |
| Onyx 2|2 ST |
732 mm |
208 mm |
332 mm |
| Onyx 3 |
843 mm |
268 mm |
392 mm |
| |
| Installation | |  |
| The luminaire is equipped with a mounting system with a tilting part for side entry or vertical installation. Locking with two stainless steel M8 screws (one M10 screw on the Onyx 2 ST). | |  |
| | |
| Photometry | |  | | EXCELLENT LUMINOUS FLUX CONTROL
The curved glass protector enables excellent flux control, reducing light pollution to a minimum. The use of glass with a low internal refraction and the shallow depth of the protector account for this excellent result. The curved protector nevertheless enables the lamp position to be lowered sufficiently to prevent the flash effect typical of flat glass. As well as improving comfort, this results in a slightly more extensive light distribution, which allows a greater distance between lighting columns.
ON SITE ADJUSTMENT
The lampholder is fitted onto a support inside the plug. Around twenty positions are possible. This flexibility enables the light distribution to be adapted to the requirements of the site to be lit (width of the road, height of the installation, etc.).
| |  | | Onyx 2 ST | |  | | The curved glass protector allows excellent flux control, reducing light pollution to a minimum by enabling the lamp position to be lowered sufficiently to prevent the flash effect typical of flat glass. As well as improving comfort, this results in a slightly more extensive light distribution, allowing a greater distance between lighting columns. Around twenty lamp positions are possible to adapt the light distribution to the requirements of the site to be lit (width of the road, height of the installation, etc.). | |  | | | |
| Light distributions | |  |
| ONYX 2/2ST : Reflector 1419 | |  |
| ONYX 3 : Reflector 1399 | |
| Options | | • Any RAL or AKZO colour • Photoelectric cell • Ø 48 mm side-entry mounting | |
| | Lamps | |
| Lamp type | Max. Power | | High Pressure Sodium | 600 W | | Mercury Vapour | 250 W | | Metal Halide | 400 W |
| |
2008 copyright© Schréder Group GIE |